Bellini CGH9501 Instruções de Operação Página 10

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 13
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 9
Bellini – 60/90cm gas hob
Rev: 8-9-2010 8
Then a particle board or similar heat
baffle must be installed under the hob
to prevent accidental touching of the
underside surface.
Leave sufficient rear clearance to
access gas and electrical connections.
ELECTRICAL CONNECTION:
Install a 10 amp general purpose
outlet (GPO) in accordance with
relevant electrical standards and/or
codes of practice applicable.
The power supply cord (supplied) must
not touch against any hot surfaces and
must be placed so that its temperature
does not exceed 75
o
C at any point
along its length.
After having installed the hotplate, the
GPO must always be in an accessible
position.
GAS CONNECTION:
Install in accordance with relevant gas standards and/or codes of
practice applicable.
Connect the elbow fitting to the appliance gas manifold connection.
For Natural gas: connect the natural gas appliance regulator
(pictured opposite) with integral test point using approved gas
thread tape or compound to the elbow fitting.
For Universal LPG: connect the brass test point adaptor (pictured
opposite) using approved gas thread tape or compound to the
elbow fitting.
Ensure the supply connection point, test point and natural gas
regulator adjustment screw (for Natural gas installation) are
accessible for testing and/or adjustment with the hotplate in the
installed position.
Where a flexible hose assembly is used, ensure it is approved to
AS/NZS 1869, Class B. Any hose assembly used must be restrained
from accidental contact with the flue outlet of an under bench oven.
After connecting to gas, check for leaks using soapy solution, never a naked flame.
Fit the duplicate data plate (supplied in separate bag) on a surface adjacent to the hotplate,
for example, the inside of the cupboard door so it is clearly visible for any service technician.
SETTING THE GAS PRESSURE:
Fit a manometer with a 6 mm rubber hose to the test point on the regulator (for natural gas).
For the Model CGH6401, light one Rapid and Auxiliary burner and adjust test point pressure
to 1.00 kPa. Turn the two burners off and on again and recheck the pressure is same as set
previously or adjust as required.